Braeburn 162026 User Manual

Browse online or download User Manual for Air purifiers Braeburn 162026. Braeburn 162026 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
162026
MEDIA
AIR CLEANER
INSTALLATION INSTRUCTIONS
BRAEBURN
®
MEDIA AIR CLEANER
IMPORTANT: A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA CARTRIDGE
FROM THE CABINET.
RETURN AIR
WARM AIR
1. Turn off electricity to furnace.
2. Remove front cover.
3. Slide media cartridge from air cleaner cabinet, and discard packing material.
4. Remove and discard existing furnace air filter.
5. Install cabinet in return air system. See typical installations.
6. Slide the media cartridge into the cabinet. Be sure the airflow arrow on the cartridge is in the same direction as the
arrow in the cabinet. The wire mesh is always on the downstream side of the filter media. Replace cover.
7. If the optional air filter gauge accessory (model 169000) is to be used, install on a vertical duct surface or on air cleaner
cover between the air cleaner and the furnace blower.
8. Turn on electricity and furnace and check performance of all equipment.
This air cleaner is designed for use in systems up to
2000 CFM. For higher airflows additional units may
be required.
FOR INSTALLATION IN THE RETURN AIR DUCT OF ANY FORCED AIR HEATING AND COOLING SYSTEM
INSTALLER: LEAVE THESE INSTRUCTIONS WITH HOME OWNER
TYPICAL INSTALLATION
24.08
13.37
22.92
25.64
8.08
23.45
15.30
Page view 0
1 2

Summary of Contents

Page 1 - TYPICAL INSTALLATION

162026MEDIAAIR CLEANERINSTALLATION INSTRUCTIONSBRAEBURN®MEDIA AIR CLEANERIMPORTANT: A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA CART

Page 2 - MAINTENANCE

LIMITED WARRANTYThe Air Cleaner Media will normally need to be replaced every 4 to 6 months (end of the heating or cooling season) with normal usage.

Comments to this Manuals

No comments