MODEL
1010
Builder Series
Non-Programmable
Single Stage Heat/Cool
Thermostat
Compatible with low voltage single stage gas,
oil or electric heating or cooling systems,
including single stage heat pumps. Do not use
this thermostat on applications with voltages
above 30 Volts AC.
© 2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 1010-100-005
WARNING!
Important Safety Information
Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating
this thermostat.
This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas,
oil or electric heating or cooling systems, including single stage heat pumps.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
The system must have 24 Volt AC power present for proper system operation and control.
Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could possibly damage the controlled cooling system and may cause
personal injury.
This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
SPECIFICATIONS
1
1
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
Accuracy: +/- 1˚ F (+/- .5˚ C)
• Compatibility with low voltage single stage gas, oil or electric heating or cooling
systems, including single stage heat pumps.
Terminations: R, C, G, Y, W, O, B
USER MANUAL
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
SPECIFICATIONS
INSTALLATION
TESTING YOUR NEW THERMOSTAT
PROGRAMMING USER SETTINGS
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
WIRING DIAGRAMS
1
2
3
4
5
6
7
Front
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - USER MANUAL

MODEL1010Builder SeriesNon-ProgrammableSingle Stage Heat/CoolThermostatCompatible with low voltage single stage gas, oil or electric heating or coolin

Page 2 - NEW THERMOSTAT

2 3INSTALLATION212. Make sure all of the wire connections are secure and are not touching any other terminal to prevent electrical shorts and pote

Page 3 - OPERATION FEATURES

4PROGRAMMINGUSER SETTINGS44.1Default Thermostat SettingsNOTE: To erase all user program settings, gently press RESET button using a paperclip or a sm

Page 4 - TROUBLESHOOTING

6 7TROUBLESHOOTING6SYMPTOM POTENTIAL SOLUTIONSYMPTOM POTENTIAL SOLUTIONThermostat turns heating or cooling system on too often or not often enough.Inc

Page 5 - Store this

8WIRING DIAGRAMS7R O BTypical Heat Pump SystemC Y W GFanControlCompressorControlReversingValve24 Volt ACTransformer120Volt ACHot Side CommonR O BTypic